Laserfiche WebLink
Alternates: <br />Should any alternate be accepted, the amount written below shall be the amount to 'add too or 'deduct from' <br />the appropriate Base Bid. Refer to Section 01030 — Alternates, the Drawings and the CM Black Bid Package <br />for complete description and delineation of alternate requirements as the descriptions below are not Intended to <br />fully convey the scopes of work. The under signed further agrees to construct the alternates as described in <br />the Contract Documents for the following prices: <br />Alternate #1: (Add / Deduct) N/A <br />Provide SCN door losers, Schlage locksets, and Von Duprin exist devices as specified in Section <br />08710 without substitution as a preferred brand. <br />Alternate 42: (Add/ Deduct) N/A <br />Provide Honeywell thermostats In accordance to Division 16 specifications of the HVAC drawings as a <br />preferred brand. <br />Alternate #3: (Add / Deduct) N/A <br />Provide Notifier fire alarm system in accordance with Division 16 specifications and Electrical Drawings <br />as a preferred brand. <br />Alternate #4: (Deduct) $7,787.00 <br />Delete Toilet 125, Shower 124, the chase wall and the wall between Toilet and Shower. The entire <br />space shall be changed to Storage 125. Storage 125 shall have sealed concrete floor finish, painted <br />walls, rubber bass, lay -in ceiling, changed finish hardware, a single 20 light fixture, and supply /return <br />air diffusers. <br />Alternate #5: (Deduct) N/A <br />Delete Tubular Daylighting Devices specified In Section 08625 and shown on the Drawings. <br />Alternate #6: (Deduct) N/A <br />Delete all of the Interior wall sconce light fixtures designated `W1" on the Electrical Drawings. <br />Alternate #7: (Deduct) $ 4 5 0. 0 0 <br />Delete the work In the two (2) Future Tenant Spaces, and to Include electric unit heaters, gas piping, <br />data /cable TV conduit, electrical service conduit, temporary power/lighting, house electrical service, <br />and sprinkler piping /heads. <br />Alternate #8: (Deduct) N/A <br />Delete the FM 200 Fire Suppression System In Ballots 128 and providing sprinkler heads Instead. <br />The undersigned acknowledges receipt of the foilovring addenda which will be considered as part of the <br />Contract Documents: <br />Addendum No. one Dated �? S /1 1 Addendum No. Dated <br />Addendum No. Two Dated 1/31 11 Addendum No. Dated <br />The undersigned further agrees to begin the work promptly and to pursue the construction of the <br />Cabarrus County Board of Elections with an adequate work force to complete the work within the <br />agreed upon time, ready for the Owner's Immediate use and occupancy. <br />Submitted this the 3rd day of February„ 2011 . <br />Name of Bidder: Heyworth Plumbing Company, Inc. <br />Corn�Aa y' <br />Title: President L 1 / Linda K. Heyworth <br />(Typed Name) <br />CM Black Construction — Bid Form Scope IN 15 -001 <br />Cabarrus County Board of Elections <br />CS] <br />Page 131 i <br />Attachment number 3 <br />Page 227 <br />' I <br />